E3Z IO-Link-sensoren gir høy funksjonalitet og enkel tilgang fra kontrollnivået takket være IO-Link-funksjoner. Sensoren, som er designet i et kompakt kabinett med avansert diagnostikk, fleksible innstillinger og standard registreringsmodi, er førstevalget innen både standard og utfordrende bruksområder.

  • Konfigurasjon og kommunikasjon via IO-Link v1.1
  • IO-Link-funksjoner med avansert diagnostikk
  • Overføringshastighet COM 2 og COM 3
  • Robust og kompakt kabinett
Spesifikasjoner & Bestillingsinfo

Ordering information

 

Sensor type

Sensing distance

Baud rate

Connection method

Order code

 

 

 

 

PNP output

Through-beam

(Emitter + Receiver)1

15 m

(Infrared light)

COM2

-

-

2 m

-

E3Z-T81-IL2 2M

Emitter:

E3Z-T81-L-IL2 2M

Receiver:

E3Z-T81-D-IL2 2M

-

-

-

⬛ M12, 0.3 m

E3Z-T81-M1TJ-IL2 0.3M

Emitter:

E3Z-T81-L-M1TJ-IL2 0.3M

Receiver:

E3Z-T81-D-M1TJ-IL2 0.3M

-

-

-

E3Z-T86-IL2

Emitter:

E3Z-T86-L-IL2

Receiver:

E3Z-T86-D-IL2

COM3

-

-

2 m

-

E3Z-T81-IL3 2M

Emitter:

E3Z-T81-L-IL3 2M

Receiver:

E3Z-T81-D-IL3 2M

-

-

-

⬛ M12, 0.3 m

E3Z-T81-M1TJ-IL3 0.3M

Emitter:

E3Z-T81-L-M1TJ-IL3 0.3M

Receiver:

E3Z-T81-D-M1TJ-IL3 0.3M

-

-

-

E3Z-T86-IL3

Emitter:

E3Z-T86-L-IL3

Receiver:

E3Z-T86-D-IL3

Retro-reflective with

MSR function2

4 m (100 mm)3

(Red light)

COM2

-

-

2 m

-

E3Z-R81-IL2 2M

-

-

-

⬛ M12, 0.3 m

E3Z-R81-M1TJ-IL2 0.3M

-

-

-

E3Z-R86-IL2

COM3

-

-

2 m

-

E3Z-R81-IL3 2M

-

-

-

⬛ M12, 0.3 m

E3Z-R81-M1TJ-IL3 0.3M

-

-

-

E3Z-R86-IL3

Diffuse-reflective

1 m

(Infrared light)

COM2

-

-

2 m

-

E3Z-D82-IL2 2M

-

-

-

⬛ M12, 0.3 m

E3Z-D82-M1TJ-IL2 0.3M

-

-

-

E3Z-D87-IL2

COM3

-

-

2 m

-

E3Z-D82-IL3 2M

-

-

-

⬛ M12, 0.3 m

E3Z-D82-M1TJ-IL3 0.3M

-

-

-

E3Z-D87-IL3

90 mm (narrow beam)

(Red light)

COM2

-

-

2 m

-

E3Z-L81-IL2 2M

-

-

-

⬛ M12, 0.3 m

E3Z-L81-M1TJ-IL2 0.3M

-

-

-

E3Z-L86-IL2

COM3

-

-

2 m

-

E3Z-L81-IL3 2M

-

-

-

⬛ M12, 0.3 m

E3Z-L81-M1TJ-IL3 0.3M

-

-

-

E3Z-L86-IL3

Note: Please contact your OMRON sales representative regarding the IO-Link setup file (IODD file).

Specifications

 

 

Sensing method

Through-beam

Retro-reflective
with MSR function

Diffuse-reflective

Narrow-beam Models

 

PNP
output

Pre-wired

E3Z-T81-IL_

E3Z-R81-IL_

E3Z-D82-IL_

E3Z-L81-IL_

Model

Pre-wired
connector (M12)

E3Z-T81-M1TJ-IL_

E3Z-R81-M1TJ-IL_

E3Z-D82-M1TJ-IL_

E3Z-L81-M1TJ-IL_

Item

Connector (M8)

E3Z-T86-IL_

E3Z-R86-IL_

E3Z-D87-IL_

E3Z-L86-IL_

Directional angle

Both emitter and receiver: 3 to 15 °

2 to 10 °

-

Light source (wavelength)

Infrared LED (870 nm)

Red LED (660 nm)

Infrared LED (860 nm)

Red LED (650 nm)

Power supply voltage

10 to 30 VDC (including 10% ripple (p-p))

Protection circuits

Reversed power supply polarity protection, output short-circuit protection, and reversed output polarity protection

Reversed power supply polarity protection, output short-circuit protection,
reversed output polarity protection, and mutual interference prevention

Response time

Operate or reset: 1 ms max.

Ambient temperature range

Operating: −25 to 55°C (with no icing or condensation)
Storage: 40 to 70 ° C (with no icing or condensation)

Degree of protection

IEC 60529 IP67

Material

Case

Polybutylene terephthalate (PBT)

Display

Modified polyarylate

Lens

Modified polyarylate

Methacrylate resin (PMMA)

Modified polyarylate

Main IO-Link functions

Operation mode switching between Light ON and Dark ON, setup of the instability detection level for light receiving and non-light receiving, timer function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting, setup of a teaching level and execution of teaching, setup of light receiving sensitivity level, monitor output, operating hours read-out, and initial reset

Communication specifications

IO-Link specification

Ver 1.1

Baud rate

  • IL3: COM3 (230.4 kbps),
  • IL2: COM2 (38.4 kbps)

Data length

PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2)

Minimum cycle time

  • IL3 (COM3): 1 ms,
  • IL2 (COM2): 2.3 ms

 

Light incident level monitor prevents false detection before it happens


1. Through-beam sensors are normally sold in sets that include both the Emitter and Receiver.

2. The Reflector is sold separately. Select the Reflector model most suited to the application.

3. The sensing distance specified is possible when the E39-R1S is used. Values in parentheses indicate the minimum required distance between the Sensor and Reflector.

1. Through-beam sensors are normally sold in sets that include both the Emitter and Receiver.

2. The Reflector is sold separately. Select the Reflector model most suited to the application.

3. The sensing distance specified is possible when the E39-R1S is used. Values in parentheses indicate the minimum required distance between the Sensor and Reflector.

Kabler og tilbehør

XS2

XS2_OEI.jpg
XS2-kontaktsett med M12-vanntette og -skjøteledninger med én ende.

XS3

XS3_OEI.jpg
XS3-kontaktsett med M8-ledninger med én ende og skjøteledninger for redusert vedlikehold.

XS5C/XS5G

XS5C_XS5G_400x400.jpg
Kontaktene av typen XS5C/XS5G-D418 IDC har blitt utviklet for rask og enkel tilkobling uten spesielle verktøy.

Y92E-S_PP

Y92E-S_OEI.jpg
IP69K-rangerte sensorkontaktledninger for næringsmiddel- og legemiddelindustrien

Har du et spørsmål?

Vi er klare til å hjelpe.

Kontakt oss

Abonner på produktoppdateringer

Nyhetsbrev om produkter, løsninger og tjenester, direkte i innboksen.

Takk for at du abonnerer på Omrons eNews. Du vil snart motta en e-post fra oss. Denne e-posten inneholder en link som aktiverer ditt abonnement. Denne metoden brukes på grunn av juridiske årsaker og til å se til at ingen kan misbruke din e-postadresse.

Vi har for tiden tekniske problemer. Ditt skjema har ikke blitt innsendt. Vi beklager så mye og håper du vil prøve igjen senere. Detaljer:

Download

Produktdokumentasjon

Last ned dataark, håndbøker og brosjyrer.

Bla gjennom nedlastingssenter

Opplæringskurs

Få opplæring fra våre beste ingeniører. Fra nybegynner til avansert nivå.

Vis opplæringskurs