F3S-TGR-CL_A/_B | Omron, Norge

Login

Please use more than 6 characters. Forgot your password? Click here to reset.

Change password

Vi har for tiden tekniske problemer. Ditt skjema har ikke blitt innsendt. Vi beklager så mye og håper du vil prøve igjen senere. Detaljer:

Download

Register

Vi har for tiden tekniske problemer. Ditt skjema har ikke blitt innsendt. Vi beklager så mye og håper du vil prøve igjen senere. Detaljer:

Download

Thank you for registering

An email to complete your account has been sent to

Return to the website

get direct access

Fill in your details below and get direct access to content on this page

Text error notification

Text error notification

Checkbox error notification

Checkbox error notification

Vi har for tiden tekniske problemer. Ditt skjema har ikke blitt innsendt. Vi beklager så mye og håper du vil prøve igjen senere. Detaljer:

Download

Thank you for your interest

You now have access to F3S-TGR-CL_A/_B

A confirmation email has been sent to

Continue to page

Please or get direct access to download this document

F3S-TGR-CL_A/_B

Features

Category 4 / 2 safety light curtain

The F3S-TGR-CL safety sensor family is simple to wire, mount and configure since all models in finger-, hand- and body protection in type 2 and type 4 are designed in the same way, providing the same set of user selectable functions.

  • Finger- or hand protection (14 or 35mm resolution)
  • Max. operating range 6m and 14m respectively
  • Type 2 or type 4 acc. EN61496-1
  • All models with external device monitoring, interlock/start/restart and multiplex optical channels
  • Advanced models for muting, blanking, pre-reset and cyclic operation (selectable via built-in dip-switches)
  • Muting lamp integrated
  • EN ISO 13849-1 – ready

Total Consistency

Consistency in every application

No need for external devices

Muting

Specifications & ordering info
Produkt Type of safety acc. IEC 61496-1 Type of sensor Detection capability Safety field height Beam gap Number of protected semiconductor outputs Number of semiconductor outputs with signalling function Maximum operating distance Minimum operating distance Time of reaction Cascadable With muting function With beam coding Type of switching output of the OSSD Special function
2 Hand detection 35 mm 1211 mm 35 mm 2 0 14 m 0.2 m 14 ms FALSE TRUE TRUE PNP Cyclic operation, Interlock, Pre-reset, Stand-alone
2 Hand detection 35 mm 329 mm 35 mm 2 0 14 m 0.2 m 14 ms FALSE TRUE TRUE PNP Cyclic operation, Interlock, Pre-reset, Stand-alone
2 Hand detection 35 mm 770 mm 35 mm 2 0 14 m 0.2 m 14 ms FALSE TRUE TRUE PNP Stand-alone
2 Hand detection 35 mm 917 mm 35 mm 2 0 14 m 0.2 m 14 ms FALSE TRUE TRUE PNP Cyclic operation, Interlock, Pre-reset, Stand-alone
2 Finger detection 14 mm 161 mm 14 mm 2 0 6 m 0.2 m 14 ms FALSE FALSE TRUE PNP Cyclic operation, Interlock, Stand-alone
2 Finger detection 14 mm 308 mm 14 mm 2 0 6 m 0.2 m 14 ms FALSE FALSE TRUE PNP Cyclic operation, Interlock, Stand-alone
2 Finger detection 14 mm 749 mm 14 mm 2 0 6 m 0.2 m 14 ms FALSE FALSE TRUE PNP Cyclic operation, Interlock, Stand-alone
2 Hand detection 35 mm 1064 mm 35 mm 2 0 14 m 0.2 m 14 ms FALSE FALSE TRUE PNP Cyclic operation, Interlock, Stand-alone
2 Hand detection 35 mm 1211 mm 35 mm 2 0 14 m 0.2 m 14 ms FALSE FALSE TRUE PNP Cyclic operation, Interlock, Stand-alone
2 Hand detection 35 mm 182 mm 35 mm 2 0 14 m 0.2 m 14 ms FALSE FALSE TRUE PNP Cyclic operation, Interlock, Stand-alone
2 Hand detection 35 mm 1505 mm 35 mm 2 0 14 m 0.2 m 14 ms FALSE FALSE TRUE PNP Cyclic operation, Interlock, Stand-alone
2 Hand detection 35 mm 1652 mm 35 mm 2 0 14 m 0.2 m 14 ms FALSE FALSE TRUE PNP Cyclic operation, Interlock, Stand-alone
2 Hand detection 35 mm 329 mm 35 mm 2 0 14 m 0.2 m 14 ms FALSE FALSE TRUE PNP Cyclic operation, Interlock, Stand-alone
2 Hand detection 35 mm 476 mm 35 mm 2 0 14 m 0.2 m 14 ms FALSE FALSE TRUE PNP Cyclic operation, Interlock, Stand-alone
2 Hand detection 35 mm 623 mm 35 mm 2 0 14 m 0.2 m 14 ms FALSE FALSE TRUE PNP Cyclic operation, Interlock, Stand-alone
2 Hand detection 35 mm 770 mm 35 mm 2 0 14 m 0.2 m 14 ms FALSE FALSE TRUE PNP Cyclic operation, Interlock, Stand-alone
2 Hand detection 35 mm 917 mm 35 mm 2 0 14 m 0.2 m 14 ms FALSE FALSE TRUE PNP Cyclic operation, Interlock, Stand-alone
4 Finger detection 14 mm 308 mm 14 mm 2 0 6 m 0.2 m 14 ms FALSE FALSE TRUE PNP Cyclic operation, Interlock, Stand-alone
4 Finger detection 14 mm 455 mm 14 mm 2 0 6 m 0.2 m 14 ms FALSE FALSE TRUE PNP Cyclic operation, Interlock, Stand-alone
4 Finger detection 14 mm 602 mm 14 mm 2 0 6 m 0.2 m 14 ms FALSE FALSE TRUE PNP Cyclic operation, Interlock, Stand-alone
4 Finger detection 14 mm 749 mm 14 mm 2 0 6 m 0.2 m 14 ms FALSE FALSE TRUE PNP Cyclic operation, Interlock, Stand-alone
4 Hand detection 35 mm 1064 mm 35 mm 2 0 14 m 0.2 m 14 ms FALSE FALSE TRUE PNP Cyclic operation, Interlock, Stand-alone
4 Hand detection 35 mm 1505 mm 35 mm 2 0 14 m 0.2 m 14 ms FALSE FALSE TRUE PNP Cyclic operation, Interlock, Stand-alone
4 Hand detection 35 mm 329 mm 35 mm 2 0 14 m 0.2 m 14 ms FALSE FALSE TRUE PNP Cyclic operation, Interlock, Stand-alone
4 Hand detection 35 mm 476 mm 35 mm 2 0 14 m 0.2 m 14 ms FALSE FALSE TRUE PNP Cyclic operation, Interlock, Stand-alone
4 Hand detection 35 mm 623 mm 35 mm 2 0 14 m 0.2 m 14 ms FALSE FALSE TRUE PNP Cyclic operation, Interlock, Stand-alone
4 Hand detection 35 mm 770 mm 35 mm 2 0 14 m 0.2 m 14 ms FALSE FALSE TRUE PNP Cyclic operation, Interlock, Stand-alone
4 Hand detection 35 mm 917 mm 35 mm 2 0 14 m 0.2 m 14 ms FALSE FALSE TRUE PNP Cyclic operation, Interlock, Stand-alone
Compare products Show more products
Muting actuators

F39-TGR-MCL

f39-tgr-mcl prod
The F39-TGR-MCL-_ muting actuators are plug-and-play accessories for the F3S-TGR-CL Safety Sensors. Easy wiring of the entire muting system is provided by connection boxes managing all connections needed.

Have a question?

We are ready to help.

Contact us

Subscribe to product updates

Newsletters about product innovations, solutions and services, directly in your inbox.

Thank you for subscribing to Omron's eNews. You will shortly receive an e-mail from us. This e-mail contains a link which activates your email newsletter subscription. This method is used due to legal issues and to make certain that no-one can abuse your e-mail address.

Vi har for tiden tekniske problemer. Ditt skjema har ikke blitt innsendt. Vi beklager så mye og håper du vil prøve igjen senere. Detaljer:

Download

Product documentation

Download datasheets, manuals and brochures.

Browse download center

Training courses

Get the training from our best engineers. Beginner to advanced level.

View training courses