Elektronisk kretsbryter
S8V-CP - Electronic Circuit Breaker
S8V-CP protects DC circuits very precisely. Overload and short circuits are accurately detected and reliably switched off
- 4- / 8-channel electronic circuit breakers with adjustable tripping currents from 2 to 10 A
- Thermomagnetic tripping characteristic
- Sequential and load-dependent start-up of the outputs to avoid high inrush currents
- Ability to switch-on high capacitive loads reliably
- Backlit buttons with multi-color LEDs indicate the output status at a glance
- Push-In Plus terminal blocks
- Space saving Value Design for Panel
- UL Class 2 model reduces the costs of applying a safety standard
Specifications & ordering info
Ordering information
Model Number Structure
Model Number Legend
Not all combinations are possible. Refer to List of Models in Ordering Information, below.
(1) Number of Outputs
Code | Number of Outputs |
---|---|
04 | 4 outputs |
08 | 8 outputs |
(2) Rated input voltage
Code | Rated input voltage |
---|---|
24 | 24 VDC |
(3) UL Class 2 output
Code | UL Class 2 output certified |
---|---|
S | Yes |
No | No |
List of Models
Unit
Number of Outputs | UL Class 2 output | Order code |
---|---|---|
4 outputs | No | S8V-CP0424 |
Yes | S8V-CP0424S | |
8 outputs | No | S8V-CP0824 |
Specifications
Item | Model Number of Outputs UL Class 2 output | S8V-CP0424 | S8V-CP0424S | S8V-CP0824 | |
---|---|---|---|---|---|
4 | 4 | 8 | |||
No | Yes | No | |||
I/O characteristics | Rated input voltage (Input voltage allowable range) | 24 VDC (20 to 30 VDC) | 24 VDC (20 to 28.8 VDC) | 24 VDC (20 to 30 VDC) | |
Allowable
input current
2
For power input terminals, use 35 A max. per pole. |
40 A | 15.2 A | 70 A | ||
Max. rated output current (per output) | 10 A | 3.8 A | 10 A | ||
Internal
voltage drop
2
A voltage drop will occur in the S8V-CP. Consider
the voltage drop at the output. |
200 mV max. | 150 mV max. | 200 mV max. | ||
Output leakage current | 10 mA max. | ||||
Power consumption
2
When
selecting the power supply, be sure to include the internal power
consumption of the S8V-CP and not just the power consumption of
the load. |
When all outputs are connected |
10 W max. (at 10 A) | 3.1 W max. (at 3.8 A) | 20 W max. (at 10 A) | |
When all output branches are tripped |
0.84 W typ. | 0.82 W typ. | 1.32 W typ. | ||
Start-up
time
2
Outputs start in order from +VO1 to +VO8. +VO1 starts after
the initialization time. Start-up delay time of each output is automatically
decided depending on the load. If the start-up delay time is over
5 s, the next output is forcibly started. |
Initialization time | 250 ms typical | |||
Start-up delay time | 50 ms to 5 s | ||||
Functions
2
Refer
to Cat. No. T226-E1 for details. |
Current
tripping function
2
Refer to Cat. No. T226-E1
for details. |
Rated output current | 2 A, 3 A, 4 A, 6 A, 8 A, 10 A | 3.8 A | 2 A, 3 A, 4 A, 6 A, 8 A, 10 A |
Cutoff current | 2.5 A, 3.5 A, 4.5 A, 6.5 A, 8.5 A, 10.5 A |
3.8 A | 2.5 A, 3.5 A, 4.5 A, 6.5 A, 8.5 A, 10.5 A |
||
Over voltage
tripping function
2
Refer to Cat. No. T226-E1
for details. |
No | Yes | No | ||
Push button (ON/OFF/RESET) with indicator | Yes (LED colors: Red/Green/Yellow) | ||||
Reset signal input (RST) | Yes (High level: 15 to 30 VDC, Low level: 0 to 5 VDC) | ||||
Alarm signal output (ALM1/ALM2) | Yes (MOS FET relay output 30 VDC max., 50 mA max.) | ||||
Insulation | Dielectric strength | 1.0 kVAC for 1 min (between all terminals and DIN rail mounting parts), current cutoff 20 mA | |||
Insulation resistance | 100 MΩ min. (between all terminals and DIN rail mounting parts) at 500 VDC | ||||
Environment | Ambient operating temperature | –25 to 70°C (Derating is required according to the temperature.) (with no condensation or icing) | |||
Storage temperature | –40 to 85°C (with no condensation or icing) | ||||
Ambient operating humidity | 5% to 96% (storage humidity: 5% to 96%) | ||||
Vibration resistance | 10 to 55 Hz, maximum 5 G, 0.42 mm half amplitude for 2 h each in X, Y, and Z directions | ||||
Shock resistance | 294 m/s2, 3 times each in ±X, ±Y, ±Z directions | ||||
Reliability | MTBF
2
MTBF
is calculated according to JEITA RCR-9102. |
13,5000 hrs typ. | 60,000 hrs typ. | 13,5000 hrs typ. | |
Life expectancy
2
Refer
to Cat. No. T226-E1 for details. |
10 years min. | ||||
Construction | Weight | 160 g max. | 170 g max. | 420 g max. | |
Cooling fan | No | ||||
Degree of protection | IP20 by EN/IEC 60529 | ||||
Standards | EMI | Conforms to EN 61000-6-3 | |||
EMS | Conforms to EN 61000-6-2 | ||||
Safety standards | UL 508 (CSA22.2 No.14-10) Listing Pol2 UL 2367 Recognition (Max. 100W per output, per Class 2 limitations) Pol2
2
UL Class 2 output applies for the S8V-CP0424S model only. CE (EN 61000-6-2, EN 61000-6-3) |
How can we help you?
If you have a question or would like to ask for a quote, please contact us or send a request.
Kontakt meg Elektronisk kretsbryter
Takk for din forespørsel. Vi vil kontakte deg så snart som mulig.
Vi har for tiden tekniske problemer. Ditt skjema har ikke blitt innsendt. Vi beklager så mye og håper du vil prøve igjen senere. Detaljer:
DownloadTilbud for Elektronisk kretsbryter
Ved å fylle ut dette skjemaet vil du motta et tilbud på det valgte produktet. Vennligst fyll inn alle obligatoriske felter. Dine personlige opplysninger vil bli behandlet konfidensielt.
Takk for din tilbudsforespørsel. Vi vil sende deg det forespurte tilbudet så snart som mulig.
Vi har for tiden tekniske problemer. Ditt skjema har ikke blitt innsendt. Vi beklager så mye og håper du vil prøve igjen senere. Detaljer:
Download