E3NX-CA

Funksjoner

Høyytelses fargemerkesensor

E3NX-CA gir pålitelig fargemerkeregistrering for både standard og utfordrende bruksområder. Det separate oppsettet for registreringshodet gjør det enkelt å tilpasse seg til monteringskravene, selv når plassen er begrenset.
  • Kan skille mellom små fargeulikheter
  • Svarhastighet på 50 μs med kontrastmodus
  • Kan bytte mellom opptil åtte minner
  • Funksjon for RGB-dataoverføring
  • Enkel opplæring med Smart Tuning i løpet av noen sekunder
  • EtherCAT-kommunikasjonsenhet for rask feltbusstilkobling
Spesifikasjoner & Bestillingsinfo

Ordering information

 

Type

Appearance

Connecting method

Inputs/outputs

Order code

NPN output

PNP output

Standard models

 

Pre-wired (2 m)

1 output

E3NX-CA11 2M

E3NX-CA41 2M

 

Wire-saving Connector

1 output

E3NX-CA6

E3NX-CA8

Advanced models

 

Pre-wired (2 m)

2 outputs + 1 input

E3NX-CA21 2M

E3NX-CA51 2M

Model for Sensor Communications Unit1

 

Connector for Sensor Communications Unit

-

E3NX-CA0

Specifications

 

Item

Type

Standard models

Advanced models

Model for Sensor Communications Unit 1

NPN output

E3NX-CA11

E3NX-CA6

E3NX-CA21

E3NX-CA0

PNP output

E3NX-CA41

E3NX-CA8

E3NX-CA51

Connecting method

Pre-wired

Wire-saving Connector

Pre-wired

Connector for Sensor Communications Unit

I/O

Outputs

1 output

2 outputs

- 2

External input

-

1 input3

Light source (wavelength)

White LED (420 to 700 nm)

Supply voltage

10 to 30 VDC, including 10% ripple (p-p)

Supplied from the connector through the Sensor Communications Unit.

Power consumption4

At Power Supply Voltage of 24 VDC

Normal mode: 960 mW max. (Current consumption: 65 mA max.)

Eco function ON: 720 mW max. (Current consumption: 30 mA max.)

Eco function LO: 800 mW max. (Current consumption: 33 mA max.)

Control output

Load power supply voltage

30 VDC max., open-collector output

-

Load current

Groups of 1 to 3 Amplifiers: 100 mA max.,

Groups of 4 to 30 Amplifiers: 20 mA max.

Residual voltage

At load current of less than 10 mA: 1 V max.

At load current of 10 to 100 mA: 2 V max.

OFF current

0.1 mA max.

Protection circuits

Power supply reverse polarity protection, output short-circuit protection, and output reverse polarity protection

Power supply reverse polarity protection

Sensing method

Contrast Mode: Light intensity discrimination for RGB (initial state/after 2-point tuning) (R+G+B light intensity discrimination for 1-point tuning)

Color Mode: RGB ratio discrimination

Response time

Super-high-speed Mode (SHS)5

Operate or reset: 50 µs (only in Contrast Mode)

High-speed Mode (HS)

Operate or reset: 250 µs

Standard Mode (Stnd)

Operate or reset: 1 ms

Giga-power Mode (GIGA)

Operate or reset: 16 ms

Sensitivity adjustment

Smart Tuning (2-point tuning, full autotuning, or 1-point tuning (1% to 99%)) or manual adjustment

Maximum connectable units

30 Units

30 Units (When connected to OMRON NJ-series Unit)

Functions

Operation mode

Contrast Mode: NO (Light-ON) or NC (Dark-ON)

Color Mode: NO (ON for match: ON for same color as registered color) or NC (ON for mismatch: ON for different color from registered color)

Timer

Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-delay timer (Counted by 0.1 s in a range of 0.1 to 0.5 ms, by 0.5 ms for 0.5 to 5 ms, and by 1 ms for 5 to 9999 ms. Default: 10 ms, Error: 0.1 ms)

Zero reset

Contrast Mode only

Negative values can be displayed. (Threshold level is shifted.)

Resetting settings6

Select from initial reset (factory defaults), user reset (saved settings), or bank reset.

Eco mode

Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed).

Bank switching

Select from banks 1 to 8.

Power tuning level

Set from 100 to 9,999. (The RGB maximum incident level at Smart Tuning is adjusted to the power tuning level.)

Output 2

-

Normal, error output, AND output, or OR output

-

External input

-

Select from input OFF, tuning, full-auto tuning, emission OFF, bank 1 and 2 switching, bank 1 through 8 switching, or zero reset.

-

Changing the displays

Threshold level and incident level, channel number and incident level, RGB display and incident level, or bank display and incident level

*1 The E3NW-ECT Sensor Communications Unit can be used, but the E3NW-CRT/CCL, E3X-DRT21-S, and E3X-CRT/ECT Sensor Communications Units cannot be used.

*2 Two sensor outputs are allocated in the programmable logic controller (PLC) I/O table. PLC operation via Communications Unit enables reading detected values and changing settings.

*3 The following details apply to the input.

 

Contact input (relay or switch)

Non-contact input (transistor)

NPN

ON: Shorted to 0 V (Sourcing current: 2 mA max.).

OFF: Open or shorted to Vcc.

ON: 1.5 V max. (Sourcing current: 2 mA max.)

OFF: Vcc - 1.5 V to Vcc (Leakage current: 0.1 mA max.)

PNP

ON: Shorted to Vcc (Sinking current: 3 mA max.).

OFF: Open or shorted to 0 V.

ON: Vcc - 1.5 V to Vcc (sinking current: 3 mA max.)

OFF: 1.5 V max. (Leakage current: 0.1 mA max.)

*4 Power consumption
At Power Supply Voltage of 10 to 30 VDC
Normal mode: 1,080 mW max. (Current consumption: 36 mA max. at 30 VDC, 74 mA max. at 10 VDC)
Eco function ON: 840 mW max. (Current consumption: 28 mA max. at 30 VDC, 50mA max. at 10 VDC)
Eco function LO: 930 mW max. (Current consumption: 31 mA max. at 30 VDC, 55 mA max. at 10 VDC)

*5 The mutual interference prevention function is disabled if the detection mode is set to Super-high-speed Mode.

*6 The bank is not reset by the user reset function or saved by the user save function.

Recommended fiber heads

Sensing method

Appearance

Sensing direction

Size

Order code

Reflective

 

Right-angle

M6

E32-C91N 2M

Through-beam

(Grooved type)

 

Array

10 mm

E32-G16 2M

Fiber amplifier connectors

Type

Appearance

Cable length

No. of conductors

Applicable fiber amplifier units

Order code

Master connector

 

2 m

3

E3NX-CA6

E3NX-CA8

E3X-CN11

Slave connector

 

1

E3X-CN12

 


1. A Sensor Communications Unit is required if you want to use the Fiber Amplifier Unit on a network.

*1 The E3NW-ECT Sensor Communications Unit can be used, but the E3NW-CRT/CCL, E3X-DRT21-S, and E3X-CRT/ECT Sensor Communications Units cannot be used.

*2 Two sensor outputs are allocated in the programmable logic controller (PLC) I/O table. PLC operation via Communications Unit enables reading detected values and changing settings.

*3 The following details apply to the input.

*4 Power consumption
At Power Supply Voltage of 10 to 30 VDC
Normal mode: 1,080 mW max. (Current consumption: 36 mA max. at 30 VDC, 74 mA max. at 10 VDC)
Eco function ON: 840 mW max. (Current consumption: 28 mA max. at 30 VDC, 50mA max. at 10 VDC)
Eco function LO: 930 mW max. (Current consumption: 31 mA max. at 30 VDC, 55 mA max. at 10 VDC)

*5 The mutual interference prevention function is disabled if the detection mode is set to Super-high-speed Mode.

*6 The bank is not reset by the user reset function or saved by the user save function.

1. A Sensor Communications Unit is required if you want to use the Fiber Amplifier Unit on a network.

Sammenligning av ytelse

Registreringsmerke

Emballasjen som brukes i mange pakkemaskiner, leveres ofte i ruller og må skjæres og tilpasses nøyaktig. For å unngå rester og feil og for å kompensere for miljømessige påvirkninger, legges et registreringsmerke (vanligvis svart eller en farge som gir maksimal kontrast til bakgrunnen) til emballasjen.

Målet med merkesensorene er å registrere disse merkene på en pålitelig måte selv under skiftende miljøforhold. En av utfordringene er den hyppige utskiftingen av emballasje og de stadige endringene på emballasjedesignen.

Hos Omron jobber vi tett med ledende produsenter av pakkemaskiner for å evaluere kravene til sensorer fra vanlig brukt emballasje i tillegg til helt nødvendig design eller materialer. I tillegg varierer ytelseskravene i henhold til det generelle maskinverdikonseptet.

Løsningsportefølje

Kompleks form- og posisjonsdetektering og synkronisert kvalitetsinspeksjon.

For posisjonerings- og maskinsynkroniseringsoppgaver som for eksempel krever gjenkjennelse av ord eller symboler, kan formen, posisjonsregistreringsfunksjonene til vision-sensorene og systemene konfigureres til å levere løsninger til de mest komplekse og utfordrende oppgavene. Vision-systemene kan også registrere registreringsmerket og utføre posisjons- og kvalitetskontroller samtidig.
  • FQ2 – enkelt og krystallklart
  • Xpectia-Lite – ytelse og enkelhet, hånd i hånd
proplus_long.jpg

Utfordrende design og fargemerking

Objekter med kompleks design eller der hvor det er lav kontrast, krever sensorer som muliggjør en enkel tilpasning mot de spesifikke kravene.
  • Forsterkere med digitalt display og avanserte signalevalueringsfunksjoner for applikasjonsoptimaliserte innstillinger.
  • Bredt utvalg av sensorhoder som passer til applikasjonen og avstandskravene
  • Hvit LED, RGB forholdssammenligning og utvidet funksjonalitet
Color_Mark_Sensors_Teaser_373x140.jpg

Standard registrering av trykte merker

For merker som vanligvis brukes innen emballering- og trykkeriindustrien. Kontrastsensorene med hvit LED har en optimalisert lysintensitet og en algoritme for RGB-forholdsevalueringen som sikrer en stabil og rask detektering.
  • Kompakt utførelse med høy fleksibilitet innen maskindesign
  • Rask responstid på 50 μs
E3ZM-V
  • Automatisk "teach" og hvit LED
Hvis du vil ha mer informasjon, kan du gå til E3ZM-V
lite_long.jpg

Har du et spørsmål?

Vi er klare til å hjelpe.

Kontakt oss

Abonner på produktoppdateringer

Nyhetsbrev om produkter, løsninger og tjenester, direkte i innboksen.

Takk for at du abonnerer på Omrons eNews. Du vil snart motta en e-post fra oss. Denne e-posten inneholder en link som aktiverer ditt abonnement. Denne metoden brukes på grunn av juridiske årsaker og til å se til at ingen kan misbruke din e-postadresse.

Vi har for tiden tekniske problemer. Ditt skjema har ikke blitt innsendt. Vi beklager så mye og håper du vil prøve igjen senere. Detaljer:

Download

Produktdokumentasjon

Last ned dataark, håndbøker og brosjyrer.

Bla gjennom nedlastingssenter

Opplæringskurs

Få opplæring fra våre beste ingeniører. Fra nybegynner til avansert nivå.

Vis opplæringskurs