S8BA Integrated battery type
Compact DC-DC UPS with DIN-rail prevents voltage drop and power failure in industrial PCs (IPC)/controllers
System reliability greatly improved because 24VDC power supply is backed up for a certain period of time in the event of voltage drop or power failure.
- Compactness, weight reduction, and long battery life realized thanks to the adoption of a lithium-ion battery.
- Push-in terminal block adopted for the power input and output I/F.
- Shutdown in conjunction with the industrial purpose computer (IPC) or controller realized by the USB/RS- 232C/I/O port installed in the UPS.
- Two types of batteries are selectable for the 480W, allowing the ideal backup time to be realized.
- A wide lineup culminating in the 960W makes it possible to provide long-lasting backup for every type of industrial controller.
Specifications & ordering info
Ordering information
Uninterruptible power supply (UPS)
20 A/480 W1 |
Communication cable
Replacement battery pack
Specifications
480 W2 |
||||||
---|---|---|---|---|---|---|
23.3 A3 |
||||||
20 A4 |
||||||
Expected battery life5 |
||||||
4 hours6 |
||||||
Lloyd‘s register/ABS/EN609457/DNV GL (Certification is pending for DNV GL) |
||||||
Backup time table (Time unit: minutes)
For devices that use the A indication, convert the capacity into W: W = A × 24
Note: The above backup times are for reference only. They may change depending on the battery life and external environment (such as temperature).
Dimensions
S8BA-24D24D120LF (120 W)
S8BA-24D24D240LF (240 W)
S8BA-24D24D360LF (360 W)
S8BA-24D24D480LF (480 W)
6.
When using in an environment at a high temperature, charging may be paused by charging temperature protection, then the charging time will be longer than specified time.
“CS” will be displayed when charging temperature protection is operated.
7.
For the S8BA-24D24D120LF, install all of the RSMN-2030, RSHN-2030, and RSEN-2030 EMC filters manufactured by TDK. For the S8BA-24D24D240LF, S8BA-24D24D360LF, or S8BA-24D24D480LF, install both the RSMN-2030 and RSHN-2030 or their equivalents. Install these filters in series to the cable connected to the DC input terminal block. When you do, do not connect anything to the GR terminal.
The effectiveness of the noise filters may be affected by the installation environment. Be sure to check effectiveness before starting operation.
6.
When using in an environment at a high temperature, charging may be paused by charging temperature protection, then the charging time will be longer than specified time.
“CS” will be displayed when charging temperature protection is operated.
7.
For the S8BA-24D24D120LF, install all of the RSMN-2030, RSHN-2030, and RSEN-2030 EMC filters manufactured by TDK. For the S8BA-24D24D240LF, S8BA-24D24D360LF, or S8BA-24D24D480LF, install both the RSMN-2030 and RSHN-2030 or their equivalents. Install these filters in series to the cable connected to the DC input terminal block. When you do, do not connect anything to the GR terminal.
The effectiveness of the noise filters may be affected by the installation environment. Be sure to check effectiveness before starting operation.
How can we help you?
If you have a question or would like to ask for a quote, please contact us or send a request.
Kontakt meg S8BA Integrated battery type
Takk for din forespørsel. Vi vil kontakte deg så snart som mulig.
Vi har for tiden tekniske problemer. Ditt skjema har ikke blitt innsendt. Vi beklager så mye og håper du vil prøve igjen senere. Detaljer:
DownloadTilbud for S8BA Integrated battery type
Ved å fylle ut dette skjemaet vil du motta et tilbud på det valgte produktet. Vennligst fyll inn alle obligatoriske felter. Dine personlige opplysninger vil bli behandlet konfidensielt.
Takk for din tilbudsforespørsel. Vi vil sende deg det forespurte tilbudet så snart som mulig.
Vi har for tiden tekniske problemer. Ditt skjema har ikke blitt innsendt. Vi beklager så mye og håper du vil prøve igjen senere. Detaljer:
DownloadSoftware
Power Attendant Lite
By installing "Power Attendant Lite(PAL)" to your computer or your system, you can automatically shut down computers (Windows) via the network. You can benefit from PAL by more function than SSD.
Simple Shutdown Software
Simple Shutdown Software (open source version) can automatically shut down computers and UPS units when an input power problem occurs (power outage, etc.). We provide this software as a free-of-charge download.Using this software and the source code, you can incorporate automatic shutdown functions in your Linux or Windows system.
UPS Setting Utility Software
The UPS Setting Utility is a software program for configuring the settings on the UPS. This utility makes it easy to change UPS settings. You can also back up the UPS settings to a file, and transfer settings to another UPS.