KM-N2
Global power monitor for mounting inside control panels
- Solve design, installation, and operation topics.
- You can measure up to four circuits with one power monitor.
- Use general-purpose CTs and handle a variety of worksites.
- Large, easy-to-read white LCD for improved visibility.
- IEC Class 0.5S high-precision measurements (Power monitor only).
Specifications & ordering info
Ordering information
Power monitor
Note: To use a commercially available current transformer, use a CT with a secondary current rating of 1 A or 5 A, and a rated load of at least 1.0 VA.
Connectable OMRON split-type Current Transformers (CTs)
Note: The CT cables connected to the CT have the following recommended characteristics:
- cross section 0.75 mm² = AWG18
- 2C (number of internal wires is two)
- 1 m long maximum.
The CT cables are not provided by Omron
Specifications
Ratings (Power monitor)
Single-phase two-wire, single-phase three-wire, three-phase three-wire, and three-phase four-wire |
||
Single-phase two-wire: 4 circuits max., Single-phase three-wire or three-phase three-wire: 2 circuits max., |
||
Single-phase, 2-wire:100 to 277 VAC |
||
General-purpose CT with a rated secondary current of 1 A or 5 A 1 |
||
Overvoltage category II, measurement category II, pollution degree 2 |
||
Industrial electromagnetic environment (EN/IEC 61326-1 Table 2) |
||
Ratings (Connectable OMRON Split-type Current Transformers (CTs))
100 MΩ min. (at 500 VDC) (Between through hole and output lead) |
|||
−20 to 55 °C, 85% max. relative humidity (with no condensation) |
|||
−30 to 90 °C, 85% max. relative humidity (with no condensation) |
Performance (Power monitor)
Total power consumption (active, regenerative, and reactive), power (active and reactive), current, voltage, power factor, and frequency |
||
0.5% (IEC 62053-22 class 0.5S) 2 |
||
2% (IEC 62053-23 class 2) 1 |
||
Single amplitude: 0.1 mm, Acceleration: 15 m/s2, Frequency: 10 to 150 Hz, 10 sweeps for 8 min each along three axes |
||
150 m/s², 3 times each in 6 directions (up/down, left/right, forward/backward) |
||
ON residual voltage: 1.5 V max. (for output current of 50 mA) |
||
If you measure more than one circuit with one Power Monitor, the number of circuits is treated as the number of connected Power Monitors. |
||
How can we help you?
If you have a question or would like to ask for a quote, please contact us or send a request.
Kontakt meg KM-N2

Takk for din forespørsel. Vi vil kontakte deg så snart som mulig.
Vi har for tiden tekniske problemer. Ditt skjema har ikke blitt innsendt. Vi beklager så mye og håper du vil prøve igjen senere. Detaljer:
DownloadTilbud for KM-N2
Ved å fylle ut dette skjemaet vil du motta et tilbud på det valgte produktet. Vennligst fyll inn alle obligatoriske felter. Dine personlige opplysninger vil bli behandlet konfidensielt.

Takk for din tilbudsforespørsel. Vi vil sende deg det forespurte tilbudet så snart som mulig.
Vi har for tiden tekniske problemer. Ditt skjema har ikke blitt innsendt. Vi beklager så mye og håper du vil prøve igjen senere. Detaljer:
Download