Spesifikasjoner & Bestillingsinfo

Ordering information

Switches

Type

Mounting direction

Conduit size

Order code

1NC/1NO (slow-action)

2NC (slow-action)

1-conduit

Front-side mounting

Pg13.5

D4BS-15FS

D4BS-1AFS

Operation keys (order separately)

Type

Order code

Horizontal mounting

 

D4BS-K1

Vertical mounting

 

D4BS-K2

Adjustable mounting
(horizontal)

 

D4BS-K3

Specifications

Degree of protection1

IP67 (EN60947-5-1)

Durability2

Mechanical: 1,000,000 operations min.
Electrical: 500,000 operations min. (10 A at 250 VAC, resistive load)

Operating speed

0.1 m/s to 0.5 m/s

Operating frequency

30 operations/min max.

Rated frequency

50/60 Hz

Contact gap

2×2 mm min.

Direct opening force3

19.61 N min. (EN60947-5-1)

Direct opening travel3

20 mm min. (EN60947-5-1)

Full stroke

23 mm min.

Conventional enclosed thermal current (Ith)

20 A (EN60947-5-1)

Conditional short-circuit current

100 A (EN60947-5-1)

Pollution degree (operating environment)

3 (EN60947-5-1)

Protection against electric shock

Class I (with ground terminal)

Ambient temperature

Operating: -40 to 80°C (with no icing)

Note: The above values are initial values.

 


1. Although the switch box is protected from dust, oil, or water penetration, do not use the D4BS in places where dust, oil, water, or chemicals may penetrate through the key hole on the head, otherwise switch damage or malfunctioning may occur.

2. The durability is for an ambient temperature of 5°C to 35°C and an ambient humidity of 40 to 70%. Contact your Omron sales representative for more detailed information on other operating environments.

3. These figures are minimum requirements for safe operation.

1. Although the switch box is protected from dust, oil, or water penetration, do not use the D4BS in places where dust, oil, water, or chemicals may penetrate through the key hole on the head, otherwise switch damage or malfunctioning may occur.

2. The durability is for an ambient temperature of 5°C to 35°C and an ambient humidity of 40 to 70%. Contact your Omron sales representative for more detailed information on other operating environments.

3. These figures are minimum requirements for safe operation.

Har du et spørsmål?

Vi er klare til å hjelpe.

Kontakt oss

Abonner på produktoppdateringer

Nyhetsbrev om produkter, løsninger og tjenester, direkte i innboksen.

Takk for at du abonnerer på Omrons eNews. Du vil snart motta en e-post fra oss. Denne e-posten inneholder en link som aktiverer ditt abonnement. Denne metoden brukes på grunn av juridiske årsaker og til å se til at ingen kan misbruke din e-postadresse.

Vi har for tiden tekniske problemer. Ditt skjema har ikke blitt innsendt. Vi beklager så mye og håper du vil prøve igjen senere. Detaljer:

Download

Produktdokumentasjon

Last ned dataark, håndbøker og brosjyrer.

Bla gjennom nedlastingssenter

Opplæringskurs

Få opplæring fra våre beste ingeniører. Fra nybegynner til avansert nivå.

Vis opplæringskurs